Hot Runner Temperature Controllers

Hot Runner Control Modules

Hitcontrols Hot Runner Controllers are designed based on high-intellect microprocessor technology. Optional LED/color LCD display, single-zone/dual zones for hot runner temperature control applications.

Specifications:

  • Power input: 85~265Vac, 50/60Hz
  • Output current/watts: 15amps, 3600watts
  • Input: type J/K
  • Temperature unit: ℃/℉
  • Setting range: 0~450℃(32~842℉)
  • Control accuracy: ±0.1%F.S
  • Mainframes: 1~24 zones
  • Compatible with DME, ITC, FastHeat, INCOE, MCS

Standard Features:

  • Auto/Manual/Standby
  • Load current/output percentage display
  • Zero cross or phase angle output
  • Soft-start, Boost function
  • High/low temperature alarm
  • Fuse blowout indicator
  • T.C & heater inverse
  • Controller locking function

LCD Hot Runner Control Module HC15-S

A controller set you apart from competitors

All operating information is displayed on the screen, instead of codes. Saving your customer most time on codes means checking. And increase their operation efficiency by 25%.

  • Color LCD display

  • Zone number display

  • 1 or 0.1 unit display resolution

  • Selectable controller state on restart

  • Automatic Switch to Manual mode if T.C failure

  • High limit of output percent

  • Remote standby or alarm output (option)

  • RS485 (option)

LED Hot Runner Control Module HC15-B

  • Thermocouple open/reverse Alarm

  • High limit of output percent

  • Heater Open/Short/Overload

  • Over current limit

  • High limit of output percent

  • Ambient temperature high alarm

  • Remote standby or alarm output (option)

  • RS485 (option)

Hot Runner Temperature Controller Mainframes

  • The Hot Runner  Mainframes, we offer the flexibility of 1, 2, 4, 6, 8, 12 to 48 zones of control at 15 Amps per zone.
  • Control nmdule could be compatible with DME, Polimold, Husky, INCOE control modules, and mainframes.
  • Mainframe input power is 380V, 3-phase at standard, option 240V, 3-phase, 1&2 zones are 240V, single phase. All components are neatly contained within the mainframe.

Tailored 5/8/12 Zone in DME style

(could be fixed in DME, Polimold, ITC floor stand )

Standard Series Mainframes

(2/4/6/8/10/12/16/20/24 zone)

Parameters
Power Supply3-phase, 240Vac, 50/60Hz

3-phase, 380Vac, 50/60Hz

Control Zones1-24 zones
Suitable ModuleHC15-B, HC15-S

Modules from DME, Athena, PCS, ITC, etc.

Max. Amps per Zone15Amps
CertificationCE, RoHS
OEM ServiceYes

Hot Runner Mainframes Features


  • Over-voltage protection

  • Reverse of sensor and heater protection

  • Short of load protection

  • Fuse blowout alarm

  • Triac breakdown alarm

  • Over rated-load alarm

  • Thermocouple open/reverse alarm

  • Optional alarm output/remote standby

  • More…

Each Mainframe Include


  • Modules
  • Connectors
  • Internal wiring & components
  • Power input line (3m at standard)
  • Output cables (3m at standard)

Hot Runner Controller FAQs

Standrad plug-in controller max. 24 zones. HMI based touch screen controller max. 120 zones.

If hot runner control modules only, quantity below 100pcs. Delivery time will be within 3-4 working days.

For controllers in full set, if quantity below 5 sets, we can finish within 3-4 working days.

Yes, it is. We have a team familiar with AI, CorelDRAW, Photoshop, will provide the best design service.

Compact single zone, dual-zone controller,

Standard controller (from 2 to 24 zones),

DME-style controller (only 5/8/12 zone available),

HMI based touch screen temperature + SVG controller (max. 120 zone).

Yes. Output electrical terminals are the same.

Yes. There are screw mounting holes backside. And the mounting dimension is same as DME mainframe.

Hot runner control module: 85-265Vac

Hot runner mainframe: 1-phase, 240Vac 1 & 2-zone), 3-phase, 380Vac, 3-phase 240Vac.

This is unvailable at present.

  • Automotive Parts
  • Medical & Pharmaceuticals
  • Consumer Electronics
  • Food and Beverage
  • Personal Care

Hot Runner Temperature Controller Trouble Shooting

1. Check the mainframe circuit breaker is working

2. Check module fuses and replace them if blown

1. Controller may not be plugged in.

2. Fuses or air circuit breaker may be blown

3. Input power incorrectly wired or damaged

1. Triac shorted or driver

2. Change parameter “t”=0 (factory setting is t=1)

3. Try this module in another good heater zone

1. Heater may be too small

2. Wrong thermocouple zone

3. Heater may open

4. Check cable connection

5. Input voltage to module is low

6. Triac open

7. Try this module in another good heater zone

1. Heater may be too small

2. Wrong thermocouple zone

3. Heater may open

4. Check cable connection

5. Input voltage to module is low

6. Triac open

7. Try this module in another good heater zone